{"id":2902,"date":"2026-05-27T16:06:17","date_gmt":"2026-05-27T14:06:17","guid":{"rendered":"https:\/\/www.dunasys.com\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/"},"modified":"2026-06-09T13:40:15","modified_gmt":"2026-06-09T11:40:15","slug":"boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene","status":"publish","type":"projet","link":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/","title":{"rendered":"Hydrogen Generator Monitoring and Control Unit"},"content":{"rendered":"\n\n\n\n<section class=\"block-hero block-hero-articles-dunasys\"\n        >\n            <div class=\"block-hero-articles-dunasys_breadcrumb\">\n            <div class=\"container\">\n                            <div class=\"breadcrumb\">\n            <ul class=\"breadcrumb-list\">\n                <li class=\"breadcrumb-list_item\">\n                    <a href=\"https:\/\/www.dunasys.com\/en\/\">Accueil<\/a>\n                <\/li>\n                                    <li class=\"breadcrumb-list_item\">Hydrogen Generator Monitoring and Control Unit<\/li>\n                            <\/ul>\n        <\/div>\n    \n            <\/div>\n        <\/div>\n        <div class=\"block-hero-articles-dunasys_content\">\n        <div class=\"container\">\n            <div class=\"grid\">\n                <div class=\"grid_title\">\n                                    \n                                \n                                        \n                                \n                    \n            <h1\n        class=\"title title-hero js-text-gradient-scroll\"\n                 data-gradient-duration=\"2.5\"        >Hydrogen Generator Monitoring and Control Unit<\/h1>\n    \n                                                \n                                    \n                \n        <div class=\"editor\"\n        >\n        <div class=\"\" data-turn-id-container=\"13f08049-1e98-4b05-8789-34d9d860d6bc\" data-is-intersecting=\"true\">Dunasys was selected to provide a monitoring and control unit for integration into a hydrogen generator developed for a client in the naval sector. Here&#8217;s how it works!<\/div>\n<p><!-- notionvc: 463021d3-8aab-49da-8da5-3a54362ee060 --><\/p>\n        <\/div>\n    \n                    <div class=\"meta\">\n                                                    <div class=\"author\">Par Guillaume Sery<\/div>\n                                                <div class=\"date\">Le 27 May 2026<\/div>\n                    <\/div>\n                <\/div>\n                                    <div class=\"grid_thumb\">\n                                    \n                                                                                                                                            \n                <picture class=\"post-img-wrapper\">\n\n                                        <source media=\"(min-width: 1024px)\" srcset=\"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-1200x0-c-default.webp 1x, https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-2400x0-c-default.webp 2x\">\n\n                                        <source media=\"(min-width: 768px)\" srcset=\"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-800x0-c-default.webp 1x, https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-1600x0-c-default.webp 2x\">\n\n                                        <img decoding=\"async\" src=\"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-400x0-c-default.webp\"\n                         srcset=\"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-400x0-c-default.webp 1x, https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222-800x0-c-default.webp 2x\"                         alt=\"g\u00e9n\u00e9rateur d'hydrog\u00e8ne\"\n                          width=\"1400\"                           height=\"947\"                           class=\"post-img\"                                                       fetchpriority=\"high\" loading=\"eager\"\n                                             >\n                <\/picture>\n                        \n                    <\/div>\n                            <\/div>\n        <\/div>\n    <\/div>\n<\/section>\n\n\n\n\n<section    \n        class=\"block-editor\"\n        >\n    <div class=\"container\">\n        <div class=\"grid\">\n            <div class=\"grid_content\">\n                <div class=\"editor\"><h2>Context &amp; Challenges<\/h2>\n<p class=\"isSelectedEnd\">Maritime and road transportation are at the center of today\u2019s environmental challenges. To reduce emissions, a manufacturer working for a client in the naval sector sought to integrate a monitoring and control unit into its hydrogen generator. The objective was to manage hydrogen production according to engine operating conditions while ensuring the highest levels of safety and reliability.<\/p>\n<h2>Our Contribution<\/h2>\n<p class=\"isSelectedEnd\">Dunasys designed a custom monitoring and control unit capable of:<\/p>\n<ul data-spread=\"false\">\n<li>Automatically controlling hydrogen production based on engine operating conditions (start-up, shutdown, temperature);<\/li>\n<li>Supervising and monitoring temperatures throughout the hydrogen transfer process up to the combustion chamber;<\/li>\n<li>Reducing fuel consumption.<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The solution was developed from scratch while leveraging proven Dunasys technologies, ensuring high levels of reliability and robustness.<\/p>\n<h2>Results &amp; Added Value<\/h2>\n<ul data-spread=\"false\">\n<li>A fully functional tabletop prototype demonstrating the technical feasibility and stability of the system.<\/li>\n<li>A first successful step into hydrogen technologies, paving the way for future sustainable mobility projects.<\/li>\n<li>A safety-first and intelligent design approach integrated from the earliest stages of development.<\/li>\n<\/ul>\n<h2>Technologies Used<\/h2>\n<ul data-spread=\"false\">\n<li>Dunasys PCI Microcontroller<\/li>\n<li>CAN Communication Protocols<\/li>\n<li>Real-Time Monitoring<\/li>\n<li>Multi-Layer Embedded Safety Architecture<\/li>\n<\/ul>\n<p><!-- notionvc: f4b60ff0-4c2c-4628-a8f1-7ba0d872306e --><\/p>\n<\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":2903,"template":"","class_list":["post-2902","projet","type-projet","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Hydrogen Generator Monitoring and Control Unit - Dunasys<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hydrogen Generator Monitoring and Control Unit - Dunasys\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/\" \/>\n<meta property=\"og:site_name\" content=\"Dunasys\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-09T11:40:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"947\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/\",\"url\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/\",\"name\":\"Hydrogen Generator Monitoring and Control Unit - Dunasys\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dunasys.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/energy-observer-2-main_060222.webp\",\"datePublished\":\"2026-05-27T14:06:17+00:00\",\"dateModified\":\"2026-06-09T11:40:15+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/projets-clients\\\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dunasys.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/energy-observer-2-main_060222.webp\",\"contentUrl\":\"https:\\\/\\\/www.dunasys.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/energy-observer-2-main_060222.webp\",\"width\":1400,\"height\":947,\"caption\":\"g\u00e9n\u00e9rateur d'hydrog\u00e8ne\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/\",\"name\":\"Dunasys\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#organization\",\"name\":\"Dunasys\",\"url\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dunasys.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dunasys-logo-group.svg\",\"contentUrl\":\"https:\\\/\\\/www.dunasys.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dunasys-logo-group.svg\",\"width\":1,\"height\":1,\"caption\":\"Dunasys\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dunasys.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hydrogen Generator Monitoring and Control Unit - Dunasys","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/","og_locale":"en_US","og_type":"article","og_title":"Hydrogen Generator Monitoring and Control Unit - Dunasys","og_url":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/","og_site_name":"Dunasys","article_modified_time":"2026-06-09T11:40:15+00:00","og_image":[{"width":1400,"height":947,"url":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/","url":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/","name":"Hydrogen Generator Monitoring and Control Unit - Dunasys","isPartOf":{"@id":"https:\/\/www.dunasys.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/#primaryimage"},"image":{"@id":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222.webp","datePublished":"2026-05-27T14:06:17+00:00","dateModified":"2026-06-09T11:40:15+00:00","breadcrumb":{"@id":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dunasys.com\/en\/projets-clients\/boitier-dacquisition-et-de-pilotage-a-son-generateur-dhydrogene\/#primaryimage","url":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222.webp","contentUrl":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/energy-observer-2-main_060222.webp","width":1400,"height":947,"caption":"g\u00e9n\u00e9rateur d'hydrog\u00e8ne"},{"@type":"WebSite","@id":"https:\/\/www.dunasys.com\/en\/#website","url":"https:\/\/www.dunasys.com\/en\/","name":"Dunasys","description":"","publisher":{"@id":"https:\/\/www.dunasys.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dunasys.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.dunasys.com\/en\/#organization","name":"Dunasys","url":"https:\/\/www.dunasys.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dunasys.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/dunasys-logo-group.svg","contentUrl":"https:\/\/www.dunasys.com\/wp-content\/uploads\/2026\/05\/dunasys-logo-group.svg","width":1,"height":1,"caption":"Dunasys"},"image":{"@id":"https:\/\/www.dunasys.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/projet\/2902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/projet"}],"about":[{"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/types\/projet"}],"version-history":[{"count":2,"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/projet\/2902\/revisions"}],"predecessor-version":[{"id":3052,"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/projet\/2902\/revisions\/3052"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/media\/2903"}],"wp:attachment":[{"href":"https:\/\/www.dunasys.com\/en\/wp-json\/wp\/v2\/media?parent=2902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}